Specifier and submittal center: Pinnacle hand dryer files for architects and bid packages
Every file you need to specify or submit a Pinnacle hand dryer is on this page. That includes cut sheets, CAD front and side views (.dwg), Revit families (.rfa), the UL 499 listing (#E212260), ADA projection data and the warranty. Copyable CSI Section 10 28 13 spec text is in our hand dryer specification guide.
Download files by model
| File | P3-12S surface-mount | PDC-R10 recessed |
|---|---|---|
| Cut sheet (specs + installation) | ||
| CAD front view | .dwg | .dwg |
| CAD side view | .dwg | .dwg |
| Revit family | .rfa | .rfa |
| Side view image | .png | .png |
| Troubleshooting & maintenance guide | Guides | Guides |
| Product page | P3-12S | PDC-R10 |
Submittal data at a glance
| P3-12S surface-mount | PDC-R10 recessed | |
|---|---|---|
| Mounting | Surface, on finished wall | Recessed into wall cavity |
| Overall dimensions | 12-25/32" W × 10-25/32" H × 4" D | 18" W × 18-1/2" H × 5-1/4" D |
| Projection from finished wall | 4" | 7/8" |
| Rough opening | Not required | 15-1/4" H × 14-1/2" W × 4" D from finished wall |
| Cover | 20-gauge stainless steel, 16-gauge galvanized base plate | 18-gauge stainless steel, beveled (12-gauge brushed optional) |
| Electrical | 120 VAC, dedicated 20 A circuit, grounded, GFI breaker recommended | 120 VAC, dedicated 20 A circuit, grounded, GFI breaker recommended |
| Total power | 1,250 W (10.4 A at 120 VAC) | 1,374 W (11.5 A at 120 VAC) |
| Heating element | 1000 W, thermal cut-out at 85 °C | 1000 W, thermal cut-out at 90 °C |
| Motor / airflow | 7500 RPM, double-insulated; 150 CFM | 7500 RPM, double-insulated; 150 CFM |
| Activation | Infrared sensor, runs only while hands are in the chamber | Infrared sensor, runs only while hands are in the chamber |
| Dry time | 12–15 seconds | 12–15 seconds |
| Weight | 12 lb | 20 lb |
| Listing | UL 499 (#E212260) | UL 499 (#E212260) |
| ADA | Compliant (4" projection) | Compliant (7/8" projection) |
| Warranty | 10 years parts, 3 years circuit board | 10 years parts, 3 years circuit board |
| Finish | Brushed stainless; powder-coated matte black or white (+$25, 2–4 weeks) | Brushed stainless; powder-coated matte black or white (+$25, 2–4 weeks) |
| Made in | Statesville, North Carolina | Statesville, North Carolina |
Electrical requirements are from the P3-12S and PDC-R10 installation manuals. The cut sheets have the full specs. Read more in hand dryer electrical requirements.
Writing the specification
- Architects and engineers (construction documents): use our CSI Section 10 28 13 hand dryer specification. It has the full three-part text (General, Products, Execution) with Pinnacle as basis of design, ready to paste into your project manual.
- District purchasing (buying dryers outright): use the hand dryer bid specification checklist. It lists measurable requirements without tying the bid to one brand.
- Choosing the mount type: see recessed vs surface-mount and recessed kits vs true recessed dryers.
- Mounting heights by age group: see ADA hand dryer requirements.
Installation notes for the contractor
- P3-12S: mounts on the finished wall with four lead anchors or toggle bolts. Wire enters through knock-outs in the back of the base (preferred) or the top and bottom of the cover.
- PDC-R10: frame a rough opening of 15-1/4" H × 14-1/2" W × 4" D from the finished wall surface. Conduit knock-outs are on the top and bottom right of the recessed box.
- Both: one dedicated 20 A circuit per dryer, properly grounded, installed per the NEC and local code. An internal power switch lets maintenance disconnect the unit for service.
- Mounting height: set by the user group. Pinnacle's installation manuals give floor-to-sensor heights of 32" (ages 4–7), 36" (7–10), 40" (10–13) and 44" (13–17 and adult women), and 46" for adult men.
Sustainability and product documents
Pinnacle dryers run only while hands are in the chamber, and Pinnacle's savings calculator estimates savings against paper towels.
Need something not listed?
Ask us for a submittal package for your project. Tell us the project name, models and quantities and we'll send the cut sheets, warranty and listing information together.
FAQ
What CSI section are hand dryers specified in?
Hand dryers are specified in MasterFormat Division 10, Section 10 28 13 (Toilet Accessories). Some manufacturers use a sub-number such as 10 28 13.13, 10 28 13.14 or 10 28 13.21. Older project manuals used Section 10800 or 10811.
Do you have Revit and CAD files?
Yes. Both models have CAD front and side views (.dwg) and Revit families (.rfa) on this page.
Are Pinnacle hand dryers UL listed?
Yes. Both models are UL 499 listed (#E212260), and the motor is CSA and UL component approved.
What rough opening does the recessed PDC-R10 need?
15-1/4" high × 14-1/2" wide × 4" deep from the finished wall surface.
What electrical service do I spec?
120 VAC on a dedicated 20 A circuit per dryer, properly grounded, with a GFI breaker recommended, per the NEC and local code.
Talk to Pinnacle about your school's restrooms
Tell us what you're working on and we'll reply with the right model, a quote and buying options (TIPS or BuyBoard).
Next step
Specifying for a school project? Request a quote for budget pricing, or see how schools buy through TIPS contract 250503 and BuyBoard 747-24. All school resources are on our schools page.
Sources: Pinnacle P3-12S and PDC-R10 cut sheets and installation manuals (linked above); Pinnacle product pages and warranty; Bradley CSI guide specification, Section 10 28 13.13 and Excel Dryer 3-part spec, Section 10811 [10 28 13] (section numbering).